Abstract

In the present review, we discuss the problem of hypersensitivity to laboratory animal allergens, which affects both animal caretakers and research personnel. Biological characteristics of the main allergens released by laboratory rodents are presented, as well as the mechanisms and clinical manifestations of hypersensivity reactions to laboratory animals. In addition, we consider main approaches aiming prevention of occupational allergy. The key measures to minimize predisposing factors are identified, such as the monitoring of the working space parameters, administrative measures, application of the principles of proper animal care, and the use of personal protective equipment, as well as timely detection and diagnosis of the disease. The necessity of in-depth study of the issue, feasibility assessment and legislative support is pointed out.

Full text avaliable in Russain only

References

  1. Newill CA, Evans R, Khoury MJ. Preemployment screening for allergy to laboratory animals: epidemiologic evaluation of its potential usefulness. J. Occup. Med. 1986; 28:1158–64.
  2. Meredith S.K., McDonald J.C. Work-related respiratory disease in the United Kingdom, 1989–1992: report on the SWORD project. Occup Med (Lond). 1994; 44 (4): 183–9
  3. Jeal H.L., Jones M.G., Cullinan P.C. Epidemiology of laboratory animal allergy. In: Sigsgaard T, Heederik D, editors. Occupational Asthma (Progress in Inflammation Research). Basel: Birkhäuser Verlag AG; 2010.
  4. D'Ovidio M.C., Wirz A., Zennaro D., Massari S., Melis P., Peri V.M., Rafaiani C., Riviello M.C., Mari A. Biological occupational allergy: Protein microarray for the study of laboratory animal allergy (LAA). AIMS Public Health. 2018; 5 (4): 352–65
  5. Jeal H., Draper A., Harris J., et al. Modified Th2 responses at high-dose exposures to allergen: using an occupational model. Am J Respir Crit Care Med 2006; 174: 21–25.
  6. Peng R.D., Paigen B., Eggleston P.A., et al. Both the variability and level of mouse allergen exposure influence the phenotype of the immune response in workers at a mouse facility. J Allergy Clin Immunol 2011; 128: 390–6.
  7. Jones M. Laboratory Animal Allergy in the Modern Era. Curr Allergy Asthma Rep. 2015 Dec; 15 (12): 73.
  8. Virtanen T., Kinnunen T., Rytkönen-Nissinen M. Mammalian lipocalin allergens-insights into their enigmatic allergenicity. Clin Exp Allergy. 2012; 42 (4): 494–504.
  9. Jeal H., Harris J., Draper A., Taylor A.N., Cullinan P., Jones M. Dual sensitization to rat and mouse urinary allergens reflects cross-reactive molecules rather than atopy. Allergy. 2009; 64 (6): 855–61.
  10. Ohman J.L. Jr, Hagberg K., MacDonald M.R., et al. Distribution of airborne mouse allergen in a major mouse breeding facility. J Allergy Clin Immunol 1994; 94: 810–7.
  11. Krop E.J., Doekes G., Stone M.J., Aalberse R.C., van der Zee J.S. Spreading of occupational allergens: laboratory animal allergens on hair-covering caps and in mattress dust of laboratory animal workers. Occup Environ Med. 2007; 64 (4): 267–72.
  12. Ramadani F., Bowen H., Upton N., Hobson P.S., Chan Y.C., Chen J.B., Chang T.W., McDonnell J.M., Sutton B.J., Fear D.J., Gould H.J. Ontogeny of human IgE-expressing B cells and plasma cells. Allergy. 2017 Jan; 72 (1): 66–76.
  13. Krop E.J.M., van de Pol M.A., Lutter R., Heederik D.J.J., Aalberse R.C., van der Zee J.S.. Dynamics in cytokine responses during the development of occupational sensitization to rats. Allergy 2010; 65: 1227–33.
  14. Portengen L., de Meer G., Doekes G., Heederik D. Immunoglobulin G4 antibodies to rat urinary allergens, sensitization and symptomatic allergy in laboratory animal workers. Clin Exp Allergy. 2004; 34 (8): 1243–50.
  15. Portengen L., Hollander A., Doekes G., de Meer G., Heederik D. Lung function decline in laboratory animal workers: the role of sensitisation and exposure. Occup Environ Med. 2003; 60 (11): 870–5.
  16. Stave G.M., Lee E.H., Darcey D.J. Laboratory animal bite anaphylaxis: a national survey: part 1: case series and review of the literature. J Occup Environ Med. 2017; 59 (8): 728–38.
  17. Stave G.M., Lee E.H., Darcey D.J.. Laboratory animal bite anaphylaxis: a national survey: part 2: treatment protocols. J Occup Environ Med. 2017; 59 (8): 739–41.
  18. Stave G.M. Occupational Animal Allergy. Curr. Allergy Asthma Rep. 2018; 18 (2): 11.
  19. Gordon S., Preece R.. Prevention of laboratory animal allergy. Occup Med (Lond). 2003; 53 (6): 371–7.
  20. Gordon S., Fisher S.W., Raymond R.H. Elimination of mouse allergens in the working environment: assessment of individually ventilated cage systems and ventilated cabinets in the containment of mouse allergens. J Allergy Clin. Immunol. 2001; 108 (2): 288–94.
  21. Renstrom A., Bjoring G., Hoglund A.U. Evaluation of individually ventilated cage systems for laboratory rodents: occupational health aspects. Lab Anim. 2001; 35 (1): 42–50.
  22. Thulin H., Bjorkdahl M., Karlsson A.S., Renstrom A. Reduction of exposure to laboratory animal allergens in a research laboratory. Ann Occup Hyg. 2002; 46 (1): 61–8.
  23. Krohn T.C., Itter G., Fosse R., Hansen A.K.. Controlling allergens in animal rooms by using curtains. J Am Assoc Lab Anim Sci. 2006 May; 45 (3): 51–3.
  24. Kaliste E., Linnainmaa M., MeklinT., Torvinen E., NevalainenA. The bedding of laboratory animals as a source of airborne contaminants. Laboratory Animals Ltd. Laboratory Animals (2004) 38, 25–37
  25. Koets M., Renström A., Zahradnik E., Bogdanovic J., Wouters I.M., van Amerongen A. Rapid one-step assays for on-site monitoring of mouse and rat urinary allergens. J Environ Monit. 2011; 13 (12): 3475–80.
  26. Heinsohn P.A., Jacobs R.R., Concoby B.A, eds. 1995. Biosafety Reference Manual. 2nd ed. Fairfax VA: American Industrial Hygiene Association.
  27. Jones M., Schofield S., Jeal H., Cullinan P. Respiratory protective equipment reduces occurrence of sensitization to laboratory animals. Occup Med (Lond). 7
  28. Renström A., Karlsson A.S., Tovey E. Nasal air sampling used for the assessment of occupational allergen exposure and the efficacy of respiratory protection. Clin Exp Allergy. 2002; 32: 1769–75.
  29. Slovak A.J., Orr R.G., Teasdale E.L. Efficacy of the helmet respirator in occupational asthma due to laboratory animal allergy (LAA). Am Ind Hyg Assoc J. 1985; 46: 411–5.
  30. Stave G.M., Darcey D.J.. Prevention of laboratory animal allergy in the United States: a national survey. J Occup Environ Med. 2012; 54: 558–63.
  31. Nicholson P.J., Mayho G.V., Roomes D., Swann A.B., Blackburn B.S. Health surveillance of workers exposed to laboratory animal allergens. Occup Med (Lond). 2010; 60 (8): 591–7.
  32. Tafuro F., Selis L., Goldoni M., Stendardo M., Mozzoni P., Ridolo E., Boschetto P., Corradi M. Biomarkers of respiratory allergy in laboratory animal care workers: an observational study. Int Arch Occup Environ Health. 2018; 91 (6): 735–44.
  33. Hewitt R.S., Smith A.D., Cowan J.O., Schofield J.C., Herbison G.P., Taylor D.R. Serial exhaled nitric oxide measurements in the assessment of laboratory animal allergy. J Asthma. 2008; 45 (2): 101–7.